    Name:T-903S Ethernet I/O(16AI)
    Data download:Click Here
      Product introduction

    16 channel analog input (0~5v or 0~20mA) , 16 bit AD  

    1 port  10M/100M Ethernet, MODBUS TCP / ENET  IEC870-5-104

    Two  RS485 or RS232 ports , MOBUS RTU , 300-38400bps 

    AC(85-265V)  or DC 24V  power supplies

    Model Number

     TENGCON T-903S (16AI)

    Physical Feature

    Dimension

    169 x 134 x 63 mm (W x H x D)

    Weight

    0.5 Kg

    Mount

    Standard rail or bolts

    Working Temperature

    From -40ºC to 85 ºC

    I/O Feature

    Built-in analog inputs

    16 (0-20mA or 0-5V)

    I/O state indicators

    44 pcs.

    Output image

    256 Byte (192 Byte for analog inputs )

    Power Supply and power output

    Power Supply

    Rated Voltage

    220V AC or 24V DC

     

    Range

    From 90V AC to 250V AC, 50Hz, or 24V DC

     

    Rated current

    40mA/220VAC(24V DC output in full-load) 

    20mA/220VAC(24V DC output in no-load)

    14mA/220VAC(24VDC output in full-load)

    Isolated power output

    Rated voltage

    24VDC

     

    Rated current

    0.2A

     

    Output resistance

    About 20 Ohm

     

    Terminals

    VOUT(24V+24V-)

    Analog input

    Input signal

    0-20mA in current input / 0-5V in voltage input

    Input configuration

    Software configurable to current or voltage input

    1 : voltage   0:current     (default:1)

    Inputs

    16

    Terminals

    (AI0.0~0.7,M; AI1.0~1.7,1M

    Input resistance

    About 258Ω

    About 200KΩ

    Indicators

    The LED indicator,

    voltage input:

    voltage <0.25V,LED indicator off

    0.75V<voltage<5V,LED indicator on

    Voltage>5V or 0.75V<voltage<5V , LED indicator flash

    current input:

    3mA<current <20mA,LED indicator on

    current>20mA or current<3mA,LED indicator flash

    Resolution

    16-bit

    Digital scope

    0-20000

    Conversion cycle

    10ms

    Communication 

    Ethernet

    1 port  (RJ45, 10M/100M adaptive,MODBUS TCP protocol)

    RS232

    1 port  (COM0, for internal test)

    RS232/485

    2 port 

    COM2, DB9 RS232 direct connect

    COM1, DB9 RS485(pin 2 is B, pin 3 is A)

    Default settings: MODBUS RTU Slave, Bode rate 19200,1,8,E, address 1

    CAN

    1 port

    DIP

    8-bits 

    Set DIP ON will force the IP address to the default

    192.168.1.99

    Run/stop switch

    2 switches 

    run/stop(in stop mode, only PLC program stopped)

    Communication indicator

    6 pcs. 

    Memory

    User program memory size

    2M Byte

    User data memory size

    2M Byte

    Back-up battery data memory

    1K Byte

    Data back-up time

    1 year

    CPU feature

    CPU frequency

    48 MHz

    Max. 72 MHz

    Minimum instruction processing time

    4 millisecond

     

    INT and Bit operation

    From 1 to 4 microsecond

     

    Floating-point algorithm

    About 40 microsecond

     

    1ms timer quantity 

    No limit

     

    Clock

    Internal clock

    Back-up battery